Before Samsara can capture VU and Driver Card data from the Stoneridge tachograph, you must configure the C-CAN parameters for remote download.
Configure the Stoneridge Tachograph for remote downloads as described in the following table:
Setting |
Description |
Recommended Setting |
---|---|---|
C-CAN |
Enable or Disable DDS over C-CAN. This setting does not impact Remote Download. |
Enable or Disable |
C-CAN Diagnostics (or A-CAN Diagnostics if the RDL device is connected on A-CAN) |
ISO is required by most current FMS systems. |
ISO |
Remote download activation status |
Enable Remote Download function activation. |
Enable |
Remote Download C CAN configuration |
Set to Enable. Make sure Remote Download A CAN configuration is set to Disable, or vice-versa. Activate Remote Download on only one CAN at a time. |
Enable |
Remote download card writing |
Disable is required. |
Disable |
Show remote download |
Set to No to enforce silent remote downloads where the driver is unaware that a remote download is taking place. Determines whether the driver is aware that a remote download is taking place or not. A value of No indicates remote downloads are silent; A value of Yes indicates the driver is notified. |
No |
Wake-up on CAN |
|
Both |
CAN Answer Request |
|
Both |
The configuration of the tachograph can be changed only by a mechanic at your Stoneridge approved workshop.
After changing any CAN parameters, it is necessary to disconnect and reconnect the tachograph power plug for the new settings to take effect.